Hardware and software complex for pre-profile selection and rehabilitation of the drone operators
Authors: Yarotsky F.D. | |
Published in issue: #6(95)/2024 | |
DOI: | |
Category: Medical sciences | Chapter: Medical equipment and devices |
|
Keywords: pulsed monochrome light, critical frequency of flicker fusion, critical frequency of flicker discrimination, complex decision-making time, nervous system lability, LCD display, Arduino Nano, professional predisposition |
|
Published: 04.01.2025 |
The project is dedicated to creation of a mobile hardware and software complex for pre-profile selection and rehabilitation of the drone operators. The device operation principle is based on monitoring the body physiological parameters, i.e. lability of the human nervous system, in candidates for the drone operator position by measuring critical frequency of flicker fusion, critical frequency of flicker discrimination and the time required to make a complex decision. The visual analyzer is rehabilitated by exposure to the pulsed light with the wavelength of 550 nm (yellow-green) and the frequency of 10 ... 15% less than the measured and registered value of the critical frequency of flicker discrimination for a specific drone operator. The device is made in the form of the VR glasses, has autonomous power supply and could be used in the field. The device successfully passed laboratory testing at the Armavir Center for Children's (Youth) Scientific and Technical Creativity.
References
[1] Baranov S.N., Kiseleva M.M. Changes in the critical flicker fusion frequency indicators in students after physical activity. Universum: psychology and education, 2017, no. 7 (37).(In Russ.). https://7universum.com/ru/psy/archive/item/4972 (accessed 15.05.2024).
[2] Orudzhova O.N., Shabunina N.V. On the requirements for devices for determining the critical frequency of light flickers. Scientific review. Technical sciences, 2018, no. 5, pp. 25–29.(In Russ.).
[3] Golubtsov K.V. Device for monitoring visual fatigue of an operator or user of a microcomputer. Patent No. RU5079U1 RF, 1997. (In Russ.).
[4] Golubtsov K.V. Device for monitoring and relieving visual fatigue of a computer operator. Patent No. RU9387U1 RF, 1999. (In Russ.).
[5] Golubtsov K.V., Aidu E.I., Sofronov P.D. et al. Device for relieving visual fatigue of a computer operator. Patent No. RU11059U1 RF, 1999. (In Russ.).
[6] Serednyakov V.E. Method for measuring the critical frequency of light flickering fusion. Patent No. RU2119764C1 RF, 1998.(In Russ.).
[7] Golubtsov K.V., Kuman I.G., Kheylo T.S. et al. Method for diagnosing visual impairments, method for restoring visual functions, and device for implementing them. Patent No. RU2189168C2 RF, 2002.(In Russ.).
[8] Tkachenko V.I., Starostin M.M., Tkachenko N.V. et al. Device for determining the degree of visual fatigue. Patent No. RU2282811C1 RF, Bulletin No. 24, 2005. (In Russ.).
[9] Kiroy V.N. Physiological methods in psychology. Rostov-on-Don, Publishing House OOO TsVVR Publ., 2003, 224 p. (In Russ.).
[10] Kamilov H.M., Kasymova M.S., Zakirkhodzhaev R.A. Use of flickering light in differential diagnostics of optic nerve pathology. Russian Medical Journal, 2012. URL: https://www.rmj.ru/articles/oftalmologiya/Ispolyzovanie_melykayuschego_sveta_pri_differencialynoy_diagnostike_patologii_zritelynogo_nerva/# (accessed May 15, 2024).
[11] Petrov V.A., Chertok A.G., Shevchenko N.M. Physiological express methods in hygienic studies. Vladivostok, Meditsina DV, 2017, 172 p. (In Russ.).
[12] Golubtsov K.V. Flickering light in diagnostics and treatment of pathological processes of the human visual system. Dis. Dr. Sci. (Med.), Odessa, 1992.(In Russ.).
[13] Bodrov V.A., Orlov V.Ya. Psychology and reliability: man in technology control systems. Moscow, Publishing house of the Institute of Psychology of the Russian Academy of Sciences, 1998, 288 p. (In Russ.).